14.1
Learn with advanced setting of "back- and latch-check"
See the prerequisites for performing a "learn" in section Auto-learn automatically sets back and
latch check (recommended) on page 68.
a Push the button once as for auto-setting.
Text 'LEARN' will show on the display. Same as for auto-setting.
b Stop the door at required open position.
c The door reverts towards closed position.
d Stop the door at required latch-check position.
e The door reverts to learn the back check.
f
Stop the door at required back-check.
g Remove the stop.
h The door reverts to closed position.
14.2
Revert to default values for "back- and latch-check"
a Disconnect batteries if any.
b Disconnect the electrical power contact.
c Press the LEARN BUTTON and keep it depressed.
d Connect the electrical power contact.
e Watch the ERROR LED.
3 s
f
Release the LEARN BUTTON after 3 seconds (LED is out).
g The BACK CHECK, LATCH CHECK and OPEN POSITION have now reverted to default values.
h Disconnect the electrical power contact.
i
Next time the electrical power is connected, a new learn is needed to be run, and the operator
will use the default values.
1007913-EI-9.0
Issue 2014-10-28
14 Changing group of parameters
75