Download Print this page

Installation Sequence - Assa Abloy SARGENT 422 Installation Instructions Manual

Cam action door closer

Advertisement

422
Cam Action Door Closer
Installation Instructions
Pull Side Door Mount Installation
4
(102)
1-1/16
(27)
1
(25)
3-7/8
(98)
C L
Hinge or Pivot

Installation Sequence

1. Using the template above, locate the holes on the door and frame.
‒ Four (4) on door for closer
‒ Two (2) on frame face for track assembly.
2. Prepare door and frame for fasteners using the "Supplied Hardware"
chart on page 2.
3. Close the "C" and "L" valves on the closer body.
4. Fasten the closer body to the door with power adjustment nut
toward the lock edge of door.
5. The slide track comes pre-assembled with the slider and end caps
in place. If using a spring stop and/or hold open device, prepare the
slide track assembly before proceeding. Refer to Adjustments on
page 7
NOTE: The end caps secure the slider, spring stop, and/or hold open
device in the slide track. Make sure the end caps are installed before
securing the slide track assembly onto the frame with the provided
screws.
6. Fasten slide track assembly to frame face with open side facing
down, and the spring stop and hold open device (if equipped)
installed toward hinge edge of door.
7. Secure the arm to the spline shaft with the silver arm screw using the
4mm allen wrench provided.
8. With the arm parallel to the door, insert the spline shaft into the top
of closer. The spline shaft will contact gear inside the closer.
For inclusive restroom/telephone booth function, refer to
page 8.
1-800-727-5477 • www.sargentlock.com
Copyright © 2023, 2024, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or
in part without the express written permission of SARGENT Manufacturing Company is prohibited. Patent
pending and/or patent www.assaabloydss.com/patents.
19-1/8 (486)
(2) #12-24 Tapped Holes for Machine Screws
or 3/32" Pilot Holes for Self Drilling Screws
11-1/8 (283)
(4) 1/4-20 Tapped Holes for Machine Screws
or 3/16" Pilot Holes for Self Drilling Screws
for Closer Body
Approved 2024-03-15
Frame Rabbet
Top of Door
1
(25)
NOTES:
y Right hand door shown
y Do not scale drawing
y Dimensions are given in inches (mm)
y Minimum ceiling clearance for unit is 1-1/2" (39mm) from
top of frame rabbet
y Maximum door opening:
‒ 140° Max. – Non-Hold Open and Hold Open track
5° = approximately 1/2 spline tooth
9. Once the spline shaft and closer gear have made contact, rotate
the arm approximately 5° (as shown in Arm Indexing chart
above) until the spline shaft slides further into the closer gear.
10. Move the arm in position under the slider stud. Insert the 5mm
hex wrench through the threaded hole in the arm and into hex
on the stud. Rotate counter-clockwise until tightened.
(See Figure 1 on page 7)
11. Slide the spline vertically in or out of the closer up to 1/2 inch
until arm is parallel to the track. Install plastic bushing on
opposite side of spline shaft with the black screw provided.
12. Slowly open the "C" and "L" valves and allow door to close to the
jamb.
13. Adjust closer power (see Pull Side power setting in the Power
Adjustment Chart on page 2), closer valves, and Hold Open
device (for 422CTHB2 models). (See page 7)
3
1-5/16
(33)
*1-1/2
(39)
3-1/2
3-5/16
(89)
(85)
2-5/16
(58)
1-3/4
(45)
*Min. Ceiling Height
Arm Indexing
RH Door LH Door
A8386 03/24 Rev 3
63-8386-6000-999
2
(51)

Advertisement

loading