13 Start-up
13.4

Auto-learn automatically sets back and latch check (recommended)

This learning is performed by pushing the LEARN BUTTON (LRN).
• Switch on the electrical power (the operator will find its closed position) and make sure the
LED is on.
0
• Before the learning procedure starts, make sure that the door has been properly closed i.e., not
by force.
• A new learn must be carried out in following situations
-
If any of the parameters SPRING PRE-TENSION and CLOSING TORQUE (CLTQ) are changed
after performing a learn.
-
If any of the arm system DIP-switches are changed.
• A confirmation by pushing the learn button is enough in following situations
-
If any changing of the MAT-dip.
-
When replacing any of the extension units.
-
When changing of Locked with/without power.
-
When changing of Lock 12/24 V.
• Learn can be carried out with activation units and locks connected.
• The back-check will be automatically adjusted to 10° and 1 second before open position. The
latch-check will be automatically adjusted to 10° and 1.5 seconds before closed position.
10°/1 s
68
0
Back-check
Issue 2014-10-28
Latch-check
10°
1.5 s
1007913-EI-9.0