Pre-Installation; General Tips/Safety Concerns; Operator/Door Handing - Assa Abloy Besam SW300 Installation And Service Manual

Swing door operator
Hide thumbs Also See for Besam SW300:
Table of Contents

Advertisement

10

Pre-installation

10.1

General tips/Safety concerns

10.1.1
General tips/Safety concerns
• If there are sharp edges after drilling the cable outlets, chamfer the edges to avoid damage to
the cables.
• For enhanced security and vandalism protection, always mount the operator access in the in-
terior of a building whenever possible.
• Make sure the ambient temperature is in the range specified in section Technical specification.
• Make sure that the power is off before installing.
• Make sure that the door leaf and the wall are properly reinforced at the installation points.
• Unpack the operator and make sure that all parts are delivered in accordance with the packing
note and that the operator is in good mechanical condition.
• Ensure proper material is being used for the door leaves and that there are no sharp edges.
Projecting parts shall not create any potential hazards. If glass is used bare glass edges shall not
come in contact with other glass. Toughened or laminated glass are suitable glasses.
• Ensure that entrapment between the driven part and the surrounding fixed parts due to the
opening movement of the driven part is avoided. The following distances are considered sufficient
to avoid entrapments for the parts of the body identified;
-
for fingers, a distance greater than 25 mm or less than 8 mm
-
for heads, a distance greater than 200 mm
-
for feet, a distance greater than 50 mm
-
and for the whole body, a distance greater than 500 mm
• The operator may be installed above or below 2.5 m from the floor level.
• The operator shall not be used with a doorset incorporating a wicket door.
10.2

Operator/Door handing

Operator/Door handing (DIN Right or DIN Left) is determined by which side the hinges are mounted
seen from the swing side.
DIN Left
1007913-EI-9.0
In all instances, where work is being done, the area is to be secured from ped-
estrian traffic, and the power removed to prevent injury.
DIN Left
Issue 2014-10-28
DIN Right
DIN Right
ILL-01625
10 Pre-installation
29