Before You Begin; Installation - Assa Abloy NORTON RIXSON 6332 Installation Instructions Manual

Full feature low energy operator
Table of Contents

Advertisement

6332 Series (PUSH Side) Power Operator

Before You Begin

y Thickness recommended for reinforcements
in hollow metal doors and frames is charted.
y This template information based upon use of
5" maximum width butt hinges.
y Maximum frame reveal is 1/8" up to 6-3/4"
maximum for 6332 units.
y Before beginning the installation, verify that
the door frame is properly reinforced and is
well anchored in the wall.
y Concealed electrical conduit and concealed
switch or sensor wires should be pulled to
the frame before proceeding.
Fasteners for Frame:
y 1/4-20 Machine screws for hollow metal and
aluminum.
y No. 14 x 2-3/4" (70mm) long sheet metal
screws for wood.

Installation

A. Mount backplate.
1. Determine right hand or left hand installation. (Figure 1)
2. Measure and mark first mounting hole according to template.
(Figure 2)
3. Attach backplate to frame with screw. Do not fully tighten screw
at this time.
For Metal Frames:
Use #7 drill and 1/4-20 tap for 1/4-20 machine screws.
For Wood Frames:
Use 3/16" drill and supplied screws for self drilling, self tapping
screws.
4. Ensure backplate is level and aligned with door frame. (Figure 3)
5. Using backplate as guide, mark and drill second hole. (Figure 3)
6. Insert second screw and tighten both screws.
7. Using backplate as a guide, drill and tap remaining eight (8) holes
in frame. (Figure 3)
8. Secure with eight (8) screws and tighten.
Remaining 8 Holes
Left Hand Shown
Copyright © 2019-2021, 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9363-0009-020 Rev 8 12/23
2nd
Hole
Approved 2024-02-13
Hollow Metal Door Frame Reinforcing
Frame Material
Recommended
12 Ga.
12 Ga.
.1046
.1046
(2.66)
(2.66)
14 Ga.
10 Ga.
.0747
.1343
(1.90)
(3.41)
16 Ga.
10 Ga.
.0598
.1343
(1.52)
(3.41)
18 Ga.
8 Ga.
.0478
.1644
(1.21)
(4.18)
Left Hand
PUSH
Figure 1
Figure 2
2nd
Hole
Figure 3
Frame
Door
Reinforcing
Min. Required
18 Ga.
.0478
(1.21)
12 Ga.
.1046
(2.66)
12 Ga.
.1046
(2.66)
10 Ga.
.1343
(3.41)
Pull Side
Push Side
Right Hand
PUSH
Right Hand Shown
Remaining 8 Holes
Right Hand Shown
1/8"
(3)
Template
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Norton rixson 6300 seriesNorton rixson 6331 series

Table of Contents