This product is to be installed internally.
Operator
Digit 1
Fire
1
Basic
1
Type of drive, digit 1.
Drive durability, digit 2.
Type of door leaf, digit 3.
Suitability for use as a fire protection
door, digit. 4
Drive safety devices, digit 5.
Special requirements for
drives/functions/fittings, digit 6.
Safety at door leaf or leaves, digit 7.
Ambient temperature, digit 8.
1007913-EI-9.0
Besam SW300 Classification to DIN 18650-1
Digit 2
Digit 3
Digit 4
3
1
1,2
3
1
0
1
swing door drive
3
1 000 000 test cycles, at 4 000 cycles/day
1
swing door
0
not suitable for use as a fire protection door
1
suitable for use as a smoke control door
2
suitable for use as a fire door
1
force limitation
2
connection for external safety systems
3
low energy
0
no special requirements
1
in escape routes with a break-out system
2
in escape routes without a break-out system
3
for self-closing fire protection doors with a break-out system
4
for self-closing fire protection doors without a break-out system.
0
no safety devices
1
with sufficiently dimensioned safety distances
2
with protection to prevent fingers being crushed, shorn off or drawn in
3
with integrated break-out unit
4
with presence sensor
4
temperature range as specified by the manufacturer
Issue 2014-10-28
Digit 5
Digit 6
Digit 7
1,2,3
0,1,2,3,4
0,1,2,3,4
1,2,3
0,1,2
0,1,2,3,4
4 Technical specifications
Digit 8
4