3.4.2 Round conductor
3.4.2.1 Round cable junction RA-C2-S1-4
Round cable junction RA-C2-S1-4 is a T connector for the RA-C3/C2-1.5HF
plug-in power adaptor cable. It makes it possible to connect a Rapid Link
module (RAMO5/RASP5) directly.
Figure 53: Round cable junction RA-C2-S1-4
The conductor contacts in the energy bus are made using insulation displace-
ment technology.
The feedthroughs enable the conductor outer diameter from 10 TO 16 mm.
Accessories (seal insert, locking clip, the fully wired bushing insert, etc.) is
included as standard.
▶
For mounting, secure the round pipe outlet on the ground using the
appropriate screws (M5).
▶
Coat the round cables with a length of 130 mm (two radial sections, one
longitudinal section) - for example with Weidmüller's AM16 stripping
tool.
→
Position the blade in such a way that the conductor insulation
will not be damaged.
▶
Cut the seals radially, place them around the cable jacket and insert the
seals into the U-shaped contour provided in the cable outlet.
→
The supplied equipment includes two pairs of seals for cable outer
diameters from 10 to 13 mm and from 13 to 16 m.
Only these matched gasket inserts guarantee the proper degree
of protection IP65 when used correctly.
→
The round cable must be laid without tension.
Install only one conductor per terminal.
Rapid Link 5 · RAMO5 · RASP5 10/19 MN034004EN www.eaton.com
3 Installation
3.4 Power bus
87