Parameter Group 7 ("Motor") - Eaton RAMO5 Manual

For rapid link 5
Hide thumbs Also See for RAMO5:
Table of Contents

Advertisement

10 Parameter list
10.4 Parameter groups for RASP

10.4.8 Parameter group 7 ("Motor")

Para-
Designation
meter
P7-01
Motor Identification
P7-02
Motor PF
P7-03
Motor Stator Resistance R1
P7-04
Motor Rotor Resistance R2
P7-05
Motor Stator Inductance d-Axis
P7-06
Motor Stator Inductance q-Axis
188
Table 41:
Parameter group 7 ("Motor")
Description
Motor Identification
When set to 1, the drive immediately carries out a non-
rotating autotune to measure the motor parameters for
optimum control and efficiency. Following completion of
the autotune, the parameter automatically returns to 0.
Note:
This function cannot be activated by using the drivesCon-
nect software! When operating with Vector Control (P6-01
= 1) this parameter must be set to the motor nameplate
power factor (P7-02) before performing auto tune.
Power factor cos ϕ of the motor
When operating with Vector Control (P7-02 = 1) this param-
eter must be set to the motor nameplate power factor.
Stator resistance of the motor
For induction and PM motors: phase to phase resistance
value [Rs] in Ohms
Rotor resistance of the motor
For induction motors: phase to phase resistance value [Rr]
in Ohms
Stator inductance of the motor, torque producing
For induction motors: Phase to phase inductance value in
Henry [H}
For PM-Motors: phase d-axis inductance value [Lsd] in
Henry [H]
Stator inductance of the motor, magnetizing
For PM-Motors: phase d-axis inductance value [Lsd] in
Henry [H]
Rapid Link 5 · RAMO5 · RASP5 10/19 MN034004EN www.eaton.com
Unit
Min
Max
-
0
1
0.50
1.00
Ohms
0
655.35
Ohms
0
655.35
mH
0
6553.5
mH
0
6553.5
DS
0
0.85
Mod
Dep
Mod
Dep
Mod
Dep
Mod
Dep

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rasp5

Table of Contents