10 Parameter list
10.3 Parameter groups for RAMO

10.3.4 Parameter group 3 ("Mechanical brake and digital inputs")

Para
Designation
meter
P3-04
Brake M-Level Release
P3-05
Brake Release Delay
P3-06
DI1 Logic
P3-07
DI2 Logic
P3-08
DI3 Logic
P3-09
DI4 Logic
P3-10
DI5 Logic
P3-11
t-dec Select B0
168
Table 30:
Parameter group 3 ("Digital inputs/outputs")
Description
Determines the time before the mechanical brake is
released.
Determines the time between the signal to close the brake
and disabling of the drive.
0 = normally open
1 = normally closed
Note:
Change only after POWER ON/OFF active
0 = normally open
1 = normally closed
Note:
Change only after POWER ON/OFF active
0 = normally open
1 = normally closed
Note:
Change only after POWER ON/OFF active
0 = normally open
1 = normally closed
Note:
Change only after POWER ON/OFF active
0 = normally open
1 = normally closed
Note:
Change only after POWER ON/OFF active
Selection deceleration ramp bit 0
External stop function
0: deactivated
1: activated
Rapid Link 5 · RAMO5 · RASP5 10/19 MN034004EN www.eaton.com
Unit
Min
Max
s
0
2.50
s
0
25.00
0
1
0
1
DS
0
0
0
0

Advertisement