10.4.9 Parameter P1-13
Manual mode
P1-13
SI1
0
–
1
No function
2
No function
3
No function
4
Stop in FWD mode for edge or
signal control
5
Stop in FWD mode with edge
control
6
No function
7
Stop in FWD mode with edge
control
8
Stop in FWD mode for edge or
signal control
Auto mode
P1-13
SI1
0
–
1
No function
2
Stop in FWD mode for edge or
signal control
3
Stop in FWD or REV mode for
edge or signal control
4
Stop in FWD mode for edge or
signal control
5
Stop in FWD mode for edge or
signal control
6
Stop in FWD mode for edge or
signal control
7
Stop in FWD mode for edge or
signal control
8
Stop in FWD mode for edge or
signal control
Table 42:
Signal detection in manual mode
SI2
–
No function
No function
No function
Stop in REV mode for edge or
signal control
Stop in FWD mode with edge
control
No function
Stop in REV mode with edge
control
Stop in REV mode for edge or
signal control
Table 43:
Signal detection in auto mode
SI2
–
No function
Stop in REV mode with edge
control
No function
Stop in REV mode with edge
control
Stop in FWD mode with edge
control
Stop in REV mode with edge
control
Stop in REV mode with edge
control
Stop in REV mode with edge
control
Rapid Link 5 · RAMO5 · RASP5 10/19 MN034004EN www.eaton.com
10.4 Parameter groups for RASP
SI3
–
No function
No function
No function
No function
Operation with fixed frequency 1
(FF1) for edge control
No function
FWD operation with fixed
frequency 1 (FF1) for edge or
signal control
FWD operation with fixed
frequency 1 (FF1) for edge or
signal control
SI3
–
No function
No function
No function
No function
Operation with fixed frequency 1
(FF1) for edge control
FWD operation with fixed
frequency 1 (FF1) for edge or
signal control
FWD operation with fixed
frequency 1 (FF1) for edge or
signal control
FWD operation with fixed
frequency 1 (FF1) for edge or
signal control
10 Parameter list
SI4
–
No function
No function
No function
No function
Operation with fixed frequency 1
(FF1) for edge control
No function
REV operation with fixed
frequency 1 (FF1) for edge or
signal control
REV operation with fixed
frequency 1 (FF1) for edge or
signal control
SI4
–
No function
No function
No function
No function
Operation with fixed frequency 1
(FF1) for edge control
REV operation with fixed
frequency 1 (FF1) for edge or
signal control
REV operation with fixed
frequency 1 (FF1) for edge or
signal control
REV operation with fixed
frequency 1 (FF1) for edge or
signal control
189