Eaton RAMO5 Manual page 185

For rapid link 5
Hide thumbs Also See for RAMO5:
Table of Contents

Advertisement

Para-
Designation
meter
P2-34
TCP Enable Service
P2-35
PLC Operation Enable
P2-36
Save Parameters @24V-ext.
P2-37
Spin Start Enable
Description
BACnet MSTP Communication
Cyber Security
Enable communications interfaces
P2-34 is a bitmap parameter where;
• 0000b = All services disabled off
• xxx1b = reserved
• xx1xb = TFTP/FTP server enable
• x1xxb = reserved
P2-34 will return to disabled state after a timeout period
(10 min/600 sec).
Enables the use of function blocks, which are created with
the function block editor.
0: Function blocks disabled
1: Function blocks enabled
List of defined parameters
1: If control voltage is present, the parameters will be
saved.
After that, the parameter is automatically set to 0.
Spin Start Enable
The drive starts from the detected motor speed.
A short start delay is possible if the rotor is stationary.
Possible values:
0: Spin Start Off
1: Spin Start On
Rapid Link 5 · RAMO5 · RASP5 10/19 MN034004EN www.eaton.com
10 Parameter list
10.4 Parameter groups for RASP
Unit
Min
Max
0
15
0
1
0
1
DS
0
0
0
181

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rasp5