SONET_Usr.bk Page 112 Wednesday, December 13, 2000 11:11 AM
Making Measurements

Performing an SDH Alarm Scan

Performing an SDH Alarm Scan
Description
This test can be performed In-Service without disturbing live traffic.
SDH Alarm Scan tests each channel for alarm free operation and identifies and
indicates any Unequipped channels.
You can configure the Scan to check for the occurrence of any Path layer BIP errors
above a chosen threshold. The channel in which an alarm occurred is highlighted if
any of the following alarms occur:
AU-LOP, HP-RDI, AU-AIS, H4 Loss of Multiframe,
TU-AIS, LP-RDI, TU-LOP
The SDH Alarm Scan display can be logged to the chosen logging device. See
1 Set up the receive SDH interface and payload as required. See "Setting SDH
HOW TO:
2 Choose
3 Choose AUTO or RX SETTINGS.
4 Choose the BIP error threshold.
5 Choose
112
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
"Logging on Demand " page 193.
Receive Interface" page 45.
SDH ALM SCAN
RX SETTINGS: The scan checks the structure set on the
display.
AUTO: The scan checks the structure being received. This can be particularly
useful when receiving mixed payloads.
to start the Alarm Scan.
START
on the
display.