Setting Error Threshold Indication

Setting Error Threshold Indication

Description
When making error measurements, you can have an indication of when an error
count or error ratio threshold has been exceeded. You can set the OmniBER 720 to
indicate this by a color change, from yellow to red, of the bar on the
display and the result on the
which the color change occurs.
The Count and Ratio selections are independent.
This function is available on the
HOW TO:
1 Choose COLOR ENHANCE RESULTS
2 Choose the COUNT THRESHOLD and RATIO THRESHOLD.
194
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
display. You can choose the thresholds at
RESULTS
OTHER
COLOR CONTROL
.
ON
GRAPH
display.