Scan list (for continuous mode only)

U2300A Series USB DAQ User's Guide
You are required to set up the scan list to include all
desired analog input channels. By default, the U2300A series
scans only CH 101 with the following settings.
Range: ±10 V
Input signal type: Single- ended
Polarity: Bipolar
The settings in channel configuration entry remain
unchanged when the desired data is sampled. You do not
need to reconfigure the channel configuration entry if you
wish to sample new data using the same order and settings.
The maximum number of entries you can set is 100. Table
below shows the structure of a scan list.

Table 3-2 Structure of a scan list with four entries

CHANNEL
RANGE
108
10
101
±5
103
±10
102
±2.5
To build a scan list
To build a scan list, follow the steps below:
• Use the ROUTe:SCAN command to define the list of
channels in the scan list. To determine what channels are
currently in the scan list, use the ROUTe:SCAN? query
command.
• Use the ROUTe:SCAN command if you wish to overwrite
the initial setting of the scan list.
• To initiate a scan sequence, use either the DIGitize or
RUN command.
To stop a scan initiated by the RUN command, use the STOP
command.
Features and Functions
POLARITY
SIGNAL TYPE
UNIP
SING
BIP
NRS
BIP
NRS
BIP
DIFF
3
45