Technical Data - Siemens SINAMICS S120 Manual

Cabinet modules liquid cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Cabinet Modules
6.4 Heat Exchanger Modules
Other options
Component
Rating plate data in English/French
Rating plate data in English/Spanish
Rating plate data in English/Italian
Rating plate data in English/Russian
Rating plate data in English/Chinese
6.4.6

Technical data

Table 6- 37
Technical data of the Heat Exchanger Modules, line voltage 3 AC 380 ... 415 V
Article No.
Deionized water circuit in the converter
Cooling power
Intake temperature
- min.
- max:
- <IP55 (drive line-up)
- IP55 (drive line-up)
Intake pressure
- min
- max
Rated flow rate
2)
Volume of liquid
Connection, intake/return
- outer diameter x wall thickness
Plant-side raw water circuit
Intake temperature
- min.
- max:
- <IP55
- IP55
Intake pressure, max.
Rated flow rate
2)
Pressure drop at the rated flow rate
Connection, intake/return
- outer diameter x wall thickness
General data
Supply voltages
- Line voltage
- Line frequency
- Electronics power supply
220
6SL3705-
0RE23-
2AA5
kW
32
°C
1)
°C
45
°C
40
bar
1.7
bar
6.0
l/min
88
dm³
20.4
mm
76.1 x 2.0
°C
5
3)
°C
38
°C
33
bar
6.0
l/min
132
kPa
50
mm
42.0 x 1.5
V
ACrms
Hz
V
DC
0RE24-
0RE27-
8AA5
2AA5
48
72
1)
1)
45
45
40
40
1.7
1.7
6.0
6.0
132
197
21.4
30.5
76.1 x 2.0
76.1 x 2.0
5
5
3)
3)
38
38
33
33
6.0
6.0
198
263
60
70
42.0 x 1.5
76.1 x 2.0
3 AC 380 -10 % ... 3 AC 415 +10 %
50 Hz
24 (20.4 ... 28.8)
Cabinet Modules liquid cooled
Equipment Manual, 04/2020, A5E37067587A
Option
T58
T60
T80
T85
T91
0RE31-
1AA5
120
1)
45
40
1.7
6.0
267
32.5
76.1 x 2.0
5
3)
38
33
6.0
445
90
76.1 x 2.0

Advertisement

Table of Contents
loading

Table of Contents