Siemens SINAMICS S120 Manual page 367

Cabinet modules liquid cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

X520 encoder interface
Table 9- 21
Connector
Connector type: 25-pin SUB D connector (pins)
Measuring current via temperature sensor connection: 2 mA
Accuracy of the temperature measurement:
1)
- KTY: ±7 °C (including evaluation)
- PT1000: ±5 °C (PT1000 tolerance class B according to EN 60751 including evaluation)
- PTC: ±5 °C (including evaluation)
Cabinet Modules liquid cooled
Equipment Manual, 04/2020, A5E37067587A
Encoder interface X520
Pin
Signal name
1
Reserved, do not use
2
Reserved, do not use
3
S2
4
S4
5
Ground
6
S1
7
S3
8
Ground
9
R1
10
Reserved, do not use
11
R2
12
Reserved, do not use
13
+Temp
1)
14
Reserved, do not use
15
Reserved, do not use
16
Reserved, do not use
17
Reserved, do not use
18
Reserved, do not use
19
Reserved, do not use
20
Reserved, do not use
21
Reserved, do not use
22
Reserved, do not use
23
Reserved, do not use
24
Ground
25
- Temp
1)
9.12 K46, Sensor Module Cabinet-Mounted SMC10
Technical data
Resolver signal A (sin+)
Inverted resolver signal A (sin-)
Ground (for internal shield)
Resolver signal B (cos+)
Inverted resolver signal B (cos-)
Ground (for internal shield)
Resolver excitation positive
Resolver excitation negative
Temperature sensor KTY84-1C130 /
PT1000 / PTC
Ground (for internal shield)
Temperature sensor KTY84-1C130 /
PT1000 / PTC
Options
365

Advertisement

Table of Contents
loading

Table of Contents