9.14 K50, Sensor Module Cabinet-Mounted SMC30

9.14
K50, Sensor Module Cabinet-Mounted SMC30
9.14.1

General information

Availability of option
This option is available for the following S120 Cabinet Modules:
● Motor Modules
Description
The SMC30 Sensor Module is used for detecting the actual motor speed. The signals
emitted by the rotary pulse encoder are converted here and made available to the closed-
loop controller via the DRIVE-CLiQ interface for evaluation purposes.
The following encoders can be connected to the SMC30 Sensor Module:
● TTL encoder
● HTL encoder
● SSI encoder
● KTY or PTC temperature sensor
Table 9- 24
Connectable encoders with supply voltage
Encoder type
HTL bipolar 24 V
HTL unipolar 24 V
TTL bipolar 24 V
TTL bipolar 5 V
TTL unipolar
SSI 24 V/5 V
Table 9- 25
374
X520 (SUB-D)
X521 (terminal)
Yes
Yes
Yes
Yes
No
Yes
Maximum encoder cable length
Encoder type
TTL
HTL unipolar
HTL bipolar
SSI
X531 (terminal)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Open-circuit moni-
toring
Yes
No
Yes
Yes
No
No
Maximum signal cable length in m
100
100
300
100
Cabinet Modules liquid cooled
Equipment Manual, 04/2020, A5E37067587A
Remote sense
No
No
No
To X520
No
No