X500, X501: DRIVE-CLiQ interface
Table 9- 4
Connector
Blanking plate for DRIVE-CLiQ interfaces (50 units) Article number: 6SL3066-4CA00-0AA0
Temperature sensor connections
Table 9- 5
X531-X536 temperature sensor inputs
Connector
Terminal
1
2
3
4
Max. connectable cross-section: 1.5 mm²
Measuring current via temperature sensor connection: approx. 0.83 mA
When connecting temperature sensors with 3 wires, a jumper must be inserted between
X53x.2 and X53x.4.
Cabinet Modules liquid cooled
Equipment Manual, 04/2020, A5E37067587A
DRIVE-CLiQ interface X500 and X501
Pin
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
Function
Function
1x2- / 2x2-wire
3 and 4-wire
+ Temp
+
(channel x)
(Channel x)
- Temp
-
(channel x)
(Channel x)
+ Temp
+ I
c
(channel y)
(constant current, posi-
tive channel x)
- Temp
- I
c
(channel y)
(constant current, nega-
tive channel x)
9.6 G51 to G54, temperature sensor module TM150
Signal name
Technical data
Temperature sensor connection for sensors with
1x2 wires
Connection of the 2nd measurement cable for
sensors with 4 wires
Temperature sensor connection for sensors with
1x2 wires
Connection of the 1st measurement cable for
sensors with 3 and 4 wires
Temperature sensor connection for sensors with
2x2, 3 and 4 wires
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Options
335

Advertisement

Table of Contents
loading