Table 22; Cced Messages Ced Messages Ciod Messages Hwr Messages; Ini001; Iod006 - Nortel Communication Server 1000E Maintenance Manual

Hide thumbs Also See for Communication Server 1000E:
Table of Contents

Advertisement

76 Clearing faults
Call Server chassis (NTDU30)
Alarm/Fan module (NTDU64)
Power Supply module (NTDU65) or air filter
Main power cord
Uninterruptible power supply (UPS)
Table 22 "Call Server fault indications" (page 76)
Server fault indicators.

Table 22

Call Server fault indications
Indicator
System messages
Visual indicators
Maintenance displays
User reports
Call Server fault indications and actions
Table 23 "Call Server faults" (page 77)
and associated actions. See
complete fault-clearing process. If you must replace equipment to clear a
fault, see
Possible indications
BSD080, 085, 086, 103
CCED messages
CED messages
CIOD messages
HWR messages

INI001, 002, 004, 005, 007

IOD006, 007, 060, 061, 291—297

NWS030, 102, 103, 142

SYS messages
SRPT 181, Major failure
Major alarm on attendant console
Red LED lit on Call Server alarm/fan module. See
module features" (page 29)
The System Utility card liquid crystal display (LCD) provides
system messages that indicate normal and fault conditions.
Interpretations of the maintenance display codes are in
the Software Input/Output Reference – System Messages
NN43001-712.
Major alarm reported by attendant
"Replacing equipment" (page 109)
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 04.01 4 June 2010
Copyright © 2004-2010 Nortel Networks. All Rights Reserved.
shows common Call
for details.
lists Call Server fault indications
"Fault clearing process" (page 71)
for instructions.
"Alarm/fan
for a

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs 1000e

Table of Contents