22 Communicating with the system
Connecting to the Media Card RS-232 maintenance port
Connect a serial cable either to the rear P2 connector or to the faceplate
connector, but not both. The card's hardware cannot support two devices
connected at the same time.
The terminal device should be configured to 9600, 8, N, 1. Configure the
flow control to "None" or a similar setting.
If the hardware flow control is enabled, you see information from the card
but the card does not respond to any keystrokes. If this happens, ensure
the flow control is set to "None", close the session, and reopen it.
Element Manager
Element Manager is a web-based interface that supports a broad range of
system management tasks, including:
•
configuration and maintenance of IP Peer and IP telephony features
•
configuration and maintenance of traditional routes and trunks
•
configuration and maintenance of numbering plans
•
configuration of Call Server data blocks (such as configuration data,
customer data, Common Equipment data, D-channels)
•
maintenance commands, system status inquiries, backup and restore
functions
•
software download, patch download, patch activation
The Element Manager web server resides on the Signaling Server and can
be accessed directly through a web browser.
For more information about Element Manager, see Element Manager
System Reference – Administration.NN43001-632.
Accessing the system
Use maintenance commands to disable, enable, and test system
components. To perform system maintenance on the CS 1000E, use the
following:
•
SDI system terminal using command line inputs.
•
Element Manager. For details on Element Manager, see Element
Manager System Reference – Administration NN43001-632 and
Signaling Server IP Line Applications Fundamentals (NN43001-125).
•
Maintenance Telephone.