ATTENTION
If you have reset the BIOS to factory defaults on an HA system,
ensure that you re-define the 'CP PM Core Location |Side|Loop|Shelf|
Information'. See
114).
Running a High Availability system
Step
Action
1
Check the card LED to verify that the Call Server card to be
replaced is inactive.
2
If the card is active, switch Call Servers in LD 135:
a In LD 135, load the program
b Enter the SCPU command to switch call servers (if
necessary)
3
In LD 135, split the CPU cores using the SPLIT command.
Procedure 15
Replacing the NTDW61 CP PM Call Processor card
Step
Action
1
If running a High Availability system
2
Perform an EDD on the active core to back up the customer
configuration database.
3
Label and remove all cables.
4
Unlock faceplate latches and remove card.
5
Remove the security dongle and insert it on the replacement
card.
6
Slide the CP PM Call processor into Slot 1 (or higher) of the
chassis.
Slot 1 provides for easiest cabling.
7
Lock in the card using the faceplate latches.
8
Reconnect all cables.
9
To install the software on the CP PM Call Processor:
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 04.01 4 June 2010
Copyright © 2004-2010 Nortel Networks. All Rights Reserved.
Replacing the NTDW61 CP PM Call Processor card 117
Figure 13 "Replace the CPU board BIOS" (page
--End--
--End--