Replacing NTDW61 CP PM Signaling Server equipment 129
The following message is displayed:
All specified files are contiguous.
Press any key to continue . . .
See
Figure 42 "mkbootrmd prompts " (page 129)
Figure 42
mkbootrmd prompts
7
Press any key.
8
Copy the files from the sub-folder they extract into, directly to the
root of the RMD.
Back up the NRS database
Before replacing a CP PM Signaling Server card, back up the NRS
database. For more information, see
database" (page
129).
Procedure 17
Backing up the NRS database
Step
Action
1
Log into NRS.
2
Select the Tools tab from the top menu.
3
On the left navigation menu select Database Backup.
4
From the Select backup action drop down menu select Manual
Backup.
5
Click Submit.
6
Ensure that the manBackup log does not indicate that there
were any errors with the backup file creation.