106 Database management
6
7
8
9
character C appears 20 times (approximately 1 minute) to avoid
a system timeout.
The system site ID, n the configuration database records being
sent, is compared to the ID on the system. If the IDs do not
match, the data is restored, but the following warning message
appears:
BKP0011
When the database restore succeeds, the system responds: OK.
If the database restore fails, the system sends one of the
following messages:
BKP0003
BKP0008
Reboot or sysload the system.
ATTENTION
Using the STAD command
Effective in CS 1000, Release 5.0, only users that have SEC_ADMIN
privileges can change the system time and date. For more
information about security enhancements, see Security Management
Fundamentals (NN43001-604).
Reset the correct time and date:
LD 2
STAD (day) (month) (year) (hour) (minute) (second)
Check the time and date entered:
TTAD
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 04.01 4 June 2010
Copyright © 2004-2010 Nortel Networks. All Rights Reserved.
The site ID in the restored data does not match
that of the system. This response is normal when
you use this procedure as part of an installation
process.
Corrective action:
Ensure that the customer data file is correct
and that you are not restoring the wrong file to
the system. If the file is correct, contact Nortel
technical support.
The received file contains invalid data.
Corrective action:
Check the transmitted data file to ensure that it is
the correct one.
Repeat the restore procedure using the XRT
command. If the procedure fails again, a corrupt
data file is a probability.
Transmission error occurred due to a timeout or
excessive line noise.
Corrective action:
Repeat the procedure.