ProMinent DULCO flex Control Original Operating Instructions page 69

Peristaltic metering pump
Table of Contents

Advertisement

Module/
Index
Name
slot
2
Contact
memory
8
1
Con‐
centra‐
tion rate
2
Actual
concen‐
tration
Tab. 42: Error / Warning
Module
Index
Name
/slot
9
1
Error
Supplementary Operating Instructions for PROFINET
Module
Identifi‐
Type
name
cation
(hex)
u8
Con‐
C0,83,8
f32
centra‐
3
tion
f32
* R = read, W = write
Module
Identifi‐
Type
name
cation
(hex)
Error /
40.85
u32
Warning
Data
Description
flow *
- see "Batch Memory"
S
Concentration setting setpoint (only
'Concentration' operating mode)
in
R
Actual value of concentration setting
'Concentration' operating
(only in
mode)
Data
Description
flow *
R
Bit
Name
0
Minimum Metering
1
Batch
2
Analog <
4mA
3
Analog >
23mA
4
Tem‐
perature
fault
5
Hose
rupture
6
-
7
-
8
-
9
-
10
-
11
-
12
-
13
Bus
error
14
System
error
®
Function
medium level is
too low
Too many
metering
strokes: >
100,000
Analogue cur‐
rent is less than
4 mA
Analogue cur‐
rent is greater
than 23 mA
Temperature
too high
Metering hose
damaged
Bus error
reported by the
module
System compo‐
nents faulty -
see display
69