ProMinent DULCO flex Control Original Operating Instructions page 40

Peristaltic metering pump
Table of Contents

Advertisement

Supplementary operating instructions for Modbus RTU
Register Designation
1200
Start/stop pump
1211
Target capacity
1215
Metering volume per batch
mode triggered
1217
Metering time for batch
1221
Metering volume per contact
mode triggered
1223
Auxiliary capacity
1225
Activate concentration mode BOOLEAN 0 - INACTIVE
1226
"Desired final concentration"
concentration mode
1229
Target operating mode
1233
Priming duration
1234
Clear counter
1235
Trigger a batch/contact cycle UINT16
1236
Delete error requiring
acknowledgement
40
Type
Display / purpose
UINT8
Bit 0 - Start/Stop via bus
(0=PUMP STOPS; 1=PUMP ACTIVE OR IN
STANDBY)
Bit 1 - Start/Stop via Modbus-TimeOut
(0=no TimeOut; 1=TimeOut)
FLOAT32
Dependent on
- dosing head fitted
- device context (e.g. set suction stroke)
- ...
FLOAT32
Specification for batch mode value range:
min. value is derived from the dosing head,
the max. value is also from the metering time set
UINT16
Min/max values are also controlled by specifying the
"Metering time for batch"
1 ... 10,000 sec
FLOAT32
Specification for contact mode
0.00 001 ... 99.99 l / Contact
FLOAT32
Dependent on
- dosing head fitted
- device context (e.g. set suction stroke)
- ...
1 - ACTIVE
FLOAT32
0.01 ... 100 000 ppm
Enum
0 - EXTERNAL STOP
1 - MANUAL
2 - CONTACT
3 - BATCH
4 - ANALOGUE
UINT16
1 ... 60 sec
Enum
0 - CLEAR STROKE COUNTER
1 - CLEAR QUANTITY COUNTER
2 - CLEAR CONTACT MEMORY
3 - CLEAR ALL COUNTERS
When a Modbus message with this register number
and user data pattern "0x5555" is received,
depending on the operating mode set, a batch or
contact cycle is triggered
UINT16
When a Modbus message with this register number
and user data pattern "0x5555" is received, all errors
requiring acknowledgement are reset