ProMinent DULCO flex Control Original Operating Instructions page 45

Peristaltic metering pump
Table of Contents

Advertisement

Register Designation
3002
Hose type
3003
Current rotor position
3014
Fan speed
3017
Power supply of Modbus unit UINT16
3018
CAN link connection error
Supplementary operating instructions for Modbus RTU
Type
Display / purpose
UINT8
Information about the hose fitted
0 - TPV, 5 bar (Pump type 0530, SP)
1 - TPV, 7 bar (Pump type 0730, SP)
2 - PUR, 5 bar (Pump type 0530, VP)
UINT8
Under certain conditions (including stroke rate <
3600 strokes / h), a progress bar appears on the dis‐
play, which shows the position of the rotor.
UINT16
Revolutions / second
Power supply of Modbus unit
UINT16
0 - CAN connection OK
1 - CAN node not found
2 - Vendor ID is incorrect
3 - Product code is incorrect
4 - Modbus register version is incorrect"
45