Parameter Descriptions
O-07 Diagnosis Trigger
Option:
[2]
Trigger
alarm/
warn.
3
3
O-08 Readout Filtering
If the speed feedback value readouts on fieldbus are fluctuating,
this function is used. Select filtered, if the function is required. A
power cycle is required for changes to take effect.
Option:
[0]
Motor Data
*
Std-Filt.
[1]
Motor Data
LP-Filter
3.10.2 O-1# Control Settings
Parameters to configure the option control word profile.
O-10 Control Word Profile
Select the interpretation of the control and status words
corresponding to the installed fieldbus. Only the selections valid
for the fieldbus installed in slot A are visible in the keypad
display.
For guidelines in selection of GE Drive profile and [1] PROFIdrive
profile, refer to the design guide of the related product.
For more guidelines in the selection of [1] PROFIdrive profile and
[5] ODVA , see the installation guide for the installed fieldbus.
Option:
[0]
*
[1]
[5]
[7]
O-13 Configurable Status Word STW
Array [16]
Option:
[0]
No function
[1]
Profile Default The function corresponds to the profile
*
98
Function:
Function:
Normal fieldbus readouts.
Filtered fieldbus readouts of the following
parameters:
Parameter DR-10 Power [kW].
Parameter DR-11 Power [hp].
Parameter DR-12 Motor Voltage.
Parameter DR-14 Motor current.
Parameter DR-16 Torque [Nm].
Parameter DR-17 Speed [RPM].
Parameter DR-22 Torque [%].
Parameter DR-25 Torque [Nm] High.
Function:
Drive Profile
PROFIdrive profile
ODVA
CANopen DSP 402
Function:
This parameter enables configuration of
bits 12–15 in the status word.
default selected in parameter O-10 Control
Word Profile.
O-13 Configurable Status Word STW
Array [16]
Option:
[2]
Alarm 68 Only Only set if alarm 68, Safe stop occurs.
[3]
Trip excl
Alarm 68
[10] T18 DI status
[11] T19 DI status
[12] T27 DI status
[13] T29 DI status
[14] T32 DI status
[15] T33 DI status
[21] Thermal
warning
[30] Brake fault
(IGBT)
[40] Out of ref
range
[49] Derate active
[60] Comparator 0
[61] Comparator 1
[62] Comparator 2
[63] Comparator 3
[64] Comparator 4
02/2016 All rights reserved.
Function:
Set if a trip occurs, except if alarm 68, Safe
stop executes the trip.
The bit indicates the status of terminal 19.
0 indicates that the terminal is low.
1 indicates that the terminal is high.
The bit indicates the status of terminal 27.
0 indicates that the terminal is low.
1 indicates that the terminal is high.
The bit indicates the status of terminal 29.
0 indicates that the terminal is low.
1 indicates that the terminal is high.
The bit indicates the status of terminal 32.
0 indicates that the terminal is low.
1 indicates that the terminal is high.
The bit indicates the status of terminal 33.
0 indicates that the terminal is low.
1 indicates that the terminal is high.
The thermal warning turns on when the
temperature exceeds the limit in the motor,
the frequency converter, the brake resistor,
or the thermistor.
Output is logic 1 when the brake IGBT is
short-circuited. Use this function to protect
the frequency converter if there is a fault
on the brake modules. Use the output/relay
to cut out the main voltage from the
frequency converter.
See parameter group LC-1# Comparators. If
comparator 0 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group LC-1# Comparators. If
comparator 1 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group LC-1# Comparators. If
comparator 2 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group LC-1# Comparators. If
comparator 3 is evaluated as TRUE, the
output goes high. Otherwise, it is low.
See parameter group LC-1# Comparators. If
comparator 4 is evaluated as TRUE, the
output goes high. Otherwise, it is low.