Parameter Descriptions
O-53 Start Select
Option:
Function:
[0]
Digital
Activates a start command via a digital input.
input
[1]
Bus
Activates a start command via the serial
communication port or network option module.
[2]
Logic
Activates a start command via the network/
AND
serial communication port and also via 1 of the
digital inputs.
Logic OR
Activates a start command via the network/
[3]
*
serial communication port or via 1 of the digital
inputs.
O-54 Reversing Select
Option:
Function:
[0]
Digital
Select control of the frequency converter
input
reverse function via the terminals (digital input)
and/or via the fieldbus.
[1]
Bus
Activates the reverse command via the serial
communication port or fieldbus optionmodule.
[2]
Logic
Activates the reverse command via the
AND
fieldbus/serial communication port and also via
1 of the digital inputs.
[3]
Logic OR
Activates the reverse command via the
*
fieldbus/serial communication port or via 1 of
the digital inputs.
O-55 Set-up Select
Option:
Function:
Select control of the frequency converter set-up
selection via the terminals (digital input) and/or
via the network.
[0]
Digital
Activates the set-up selection via a digital input.
input
[1]
Bus
Activates the set-up selection via the serial
communication port or network option module.
[2]
Logic
Activates the set-up selection via the network/
AND
serial communication port and via 1 of the
digital inputs.
[3]
Logic OR
Activates the set-up selection via the network/
*
serial communication port or via 1 of the digital
inputs.
O-56 Preset Reference Select
Option:
Function:
Select control of the preset reference selection
via the terminals (digital input) and/or via the
network.
[0]
Digital
Activates preset reference selection via a digital
input
input.
DET-618D
AF-650 GP™ Programming Guide
O-56 Preset Reference Select
Option:
[1]
Bus
[2]
Logic AND Activates preset reference selection via the
[3]
Logic OR
*
O-57 Profidrive OFF2 Select
Select control of the frequency converter OFF2 selection via the
terminals (digital input) and/or via the fieldbus. This parameter is
active only when parameter O-01 Control Site is set to [0] Digital
and ctrl. word, and parameter O-10 Control Word Profile is set to
[1] Profidrive profile.
Option:
[0]
[1]
[2]
[3]
*
O-58 Profidrive OFF3 Select
Select control of the frequency converter OFF3 selection via the
terminals (digital input) and/or via the fieldbus. This parameter is
active only when parameter O-01 Control Site is set to [0] Digital
and ctrl. word, and parameter O-10 Control Word Profile is set to
[1] Profidrive profile.
Option:
[0]
[1]
[2]
[3]
*
3.10.6 O-8# Drive Port Diagnostics
O-80 Bus Message Count
Range:
0
[0 - 0] This parameter shows the number of valid
*
O-81 Bus Error Count
Array [6]
Range:
0
[0 - 0] This parameter shows the number of messages with
*
02/2016 All rights reserved.
Function:
Activates preset reference selection via the
serial communication port or network option
module.
network/serial communication port and via 1 of
the digital inputs.
Activates the preset reference selection via the
network/serial communication port or via 1 of
the digital inputs.
Function:
Digital input
Bus
Logic AND
Logic OR
Function:
Digital input
Bus
Logic AND
Logic OR
Function:
messages detected on the network.
Function:
faults (for example CRC fault) detected on the
network.
3
3
105