3.12 PB-## Profibus

Parameter group related to Field Installed Profibus DP
Network Communications Option Module.
PB-00 Setpoint
Range:
Function:
0
[0 -
This parameter receives cyclical reference from a
*
65535]
Master Class 2. If the control priority is set to
Master Class 2, the reference for the frequency
converter is taken from this parameter, whereas
the cyclical reference will be ignored.
PB-07 Actual Value
Range:
Function:
0
[0 - 65535] This parameter delivers the MAV for a Master
*
Class 2. The parameter is valid if the control
priority is set to Master Class 2.
PB-15 PCD Write Configuration
Array [10]
Option:
[0]
None
*
[7]
Accel Time 1
[8]
Decel Time 1
[15]
Motor Speed High Limit
[Hz]
[16]
Motor Speed Low Limit
[Hz]
[17]
Motor Speed High Limit
[RPM]
[18]
Motor Speed Low Limit
[RPM]
[40]
Torque Limiter (Driving)
[41]
Torque Limiter (Braking)
[52]
Minimum Reference
[53]
Maximum Reference
[62]
Catch up/slow Down
Value
[110]
Accel Time 2
[111]
Decel Time 2
[163]
Term. 29 High Ref./
Feedb. Value
DET-618D
AF-650 GP™ Programming Guide
Function:
Select the parameters to be
assigned to PCD 3–10 of the
messages. The number of
available PCDs depend on the
message type. The values in
PCD 3–10 are then written to
the selected parameters as
data values. Alternatively,
specify a standard PROFIBUS
message in
parameter PB-22 Telegram
Selection.
02/2016 All rights reserved.
PB-15 PCD Write Configuration
Array [10]
Option:
[168]
Term. 33 High Ref./
Feedb. Value
[190]
Digital & Relay Bus
Control
[193]
Pulse Out #27 Bus
Control
[195]
Pulse Out #29 Bus
Control
[197]
Pulse Out #X30/6 Bus
Control
[222]
Jog Accel/Decel Time
[223]
Quick Stop Decel Time
[615]
Terminal 53 High Ref./
Feedb. Value
[625]
Terminal 54 High Ref./
Feedb. Value
[653]
Terminal 42 Output Bus
Control
[663]
Terminal X30/8 Bus
Control
[748]
PCD Feed Forward
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[1280] Fieldbus CTW 1
[1282] Fieldbus REF 1
[1285] Drive Port CTW 1
[1286] Drive Port REF 1
PB-16 PCD Read Configuration
[10] Array
Option:
[0]
None
*
[515]
Readout: Actual Set-up
[1200] Control Word
[1201] Reference [Unit]
[1202] Reference %
[1203] Status Word
[1205] Main Actual Value [%]
[1209] Custom Readout
[1210] Power [kW]
[1211] Power [hp]
Function:
Function:
Select the parameters to be
assigned to PCD 3–10 of
the messages. The number
of available PCDs depend
on the message type. PCDs
3–10 contain the actual
data values of the selected
parameters. For standard
PROFIBUS messages, see
parameter PB-22 Telegram
Selection.
111