Parameter Descriptions
LC-02 Stop Event
Select the boolean (true or false) input to deactivate Logic
Controller.
Option:
Function:
[43]
Ok key
[OK] is pressed. Only available on
the graphical LCP.
[44]
Reset key
[Reset] is pressed. Only available on
the graphical LCP.
[45]
Left key
[◄] is pressed. Only available on the
graphical LCP.
[46]
Right key
[►] is pressed. Only available on the
graphical LCP.
[47]
Up key
[
graphical LCP.
[48]
Down key
[
graphical LCP.
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5
[70]
Logic Controller
Logic Controller timer 3 is timed
Time-out 3
out.
[71]
Logic Controller
Logic Controller timer 4 is timed
Time-out 4
out.
[72]
Logic Controller
Logic Controller timer 5 is timed
Time-out 5
out.
[73]
Logic Controller
Logic Controller timer 6 is timed
Time-out 6
out.
[74]
Logic Controller
Logic Controller timer 7 is timed
Time-out 7
out.
[75]
Start command
given
[76]
Digital input x30 2
[77]
Digital input x30 3
[78]
Digital input x30 4
[90]
ATEX OL cur.
Available, if
warning
parameter F-10 Electronic Overload is
set to [20] ATEX ETR or [21]
Advanced ETR. If the alarm 164, ATEX
ETR cur.lim.alarm is active, the
output is 1.
[91]
ATEX OL cur. alarm
Available, if
parameter F-10 Electronic Overload is
set to [20] ATEX ETR or [21]
Advanced ETR. If alarm 166, ATEX
ETR freq.lim.alarm is active, the
output is 1.
[92]
ATEX OL freq.
Available, if
warning
parameter F-10 Electronic Overload is
set to [20] ATEX ETR or [21]
Advanced ETR. If alarm 163, ATEX
DET-618D
AF-650 GP™ Programming Guide
] is pressed. Only available on the
] is pressed. Only available on the
02/2016 All rights reserved.
LC-02 Stop Event
Select the boolean (true or false) input to deactivate Logic
Controller.
Option:
Function:
ETR cur.lim.warning is active, the
output is 1.
[93]
ATEX OL freq. alarm
Available, if
parameter F-10 Electronic Overload is
set to [20] ATEX ETR or [21]
Advanced ETR. If warning 165, ATEX
ETR freq.lim.warning is active, the
output is 1.
[94]
RS Flipflop 0
See chapter 3.20.2 LC-1#
Comparators.
[95]
RS Flipflop 1
See chapter 3.20.2 LC-1#
Comparators.
[96]
RS Flipflop 2
See chapter 3.20.2 LC-1#
Comparators.
[97]
RS Flipflop 3
See chapter 3.20.2 LC-1#
Comparators.
[98]
RS Flipflop 4
See chapter 3.20.2 LC-1#
Comparators.
[99]
RS Flipflop 5
See chapter 3.20.2 LC-1#
Comparators.
[100] RS Flipflop 6
See chapter 3.20.2 LC-1#
Comparators.
[101] RS Flipflop 7
See chapter 3.20.2 LC-1#
Comparators.
[102] Relay 1
[103] Relay 2
[108] Relay 7
X34/Relay Option OPCRLY
[109] Relay 8
X34/Relay Option OPCRLY
[110] Relay 9
X34/Relay Option OPCRLY
LC-03 Reset Logic Controller
Option:
Function:
[0]
Do not reset Logic
Retains programmed settings in LC-
*
Controller
## Logic Controller .
[1]
Reset Logic
Resets all parameters in LC-## Logic
Controller
Controller to default settings.
3.20.2 LC-1# Comparators
Parameters to configure the Logic Controller (LC)
comparators. Comparators are used for comparing
variables with fixed preset values.
3
3
137