Parameter Descriptions
E-70 Terminal 27 Pulse Output Variable
Option:
Function:
[100] Output frequency
[101] Reference
[102] Feedback
[103] Motor Current
[104] Torque rel to limit
[105] Torq relate to rated
[106] Power
[107] Speed
[108] Torque
[109] Max Out Freq
[119] Torque % lim
E-72 Pulse Output Max Freq #27
Range:
Function:
5000 Hz
[0 - 32000
Set the maximum frequency for terminal
*
Hz]
27, corresponding to the output variable
selected in parameter E-70 Terminal 27
Pulse Output Variable.
E-73 Terminal 29 Pulse Output Variable
Option:
Function:
[0]
No operation
Select the display output for terminal
*
29.
[45]
Bus ctrl.
[48]
Bus ctrl., timeout
[100] Output frequency
[101] Reference
[102] Feedback
[103] Motor Current
[104] Torque rel to limit
[105] Torq relate to rated
[106] Power
[107] Speed
[108] Torque
[109] Max Out Freq
[119] Torque % lim
E-75 Terminal X30/6 Pulse Output Variable
Option:
Function:
[0]
No operation
Select the variable for read-out on
*
terminal X30/6.
This parameter cannot be adjusted
while the motor is running.
This parameter is active when option
module MCB 101 is installed in the
frequency converter.
[45]
Bus ctrl.
[48]
Bus ctrl., timeout
[100] Output frequency
[101] Reference
[102] Feedback
[103] Motor Current
DET-618D
AF-650 GP™ Programming Guide
E-75 Terminal X30/6 Pulse Output Variable
Option:
[104] Torque rel to limit
[105] Torq relate to rated
[106] Power
[107] Speed
[113] Ext. Closed Loop 1
[114] Ext. Closed Loop 2
[115] Ext. Closed Loop 3
E-76 Terminal X30/6 Pulse Output Variable
Select the variable for readout on terminal X30/6.
This parameter is active when General Purpose I/O OPCGPIO is
installed in the frequency converter.
Option:
[0]
*
[45]
[48]
[100]
[101]
[102]
[103]
[104]
[105]
[106]
[107]
[108]
[109]
[119]
E-78 Pulse Output Max Freq #X30/6
Range:
5000
Hz
*
3.4.6 E-8# 24 V Encoder Input
Parameters to configure the Encoder outputs.
E-80 Term 32/33 Pulses Per Revolution
Range:
1024
*
02/2016 All rights reserved.
Function:
No operation
Bus ctrl.
Bus ctrl., timeout
Output frequency
Reference
Feedback
Motor Current
Torque rel to limit
Torq relate to rated
Power
Speed
Torque
Max Out Freq
Torque % lim
Function:
NOTICE
[0 -
32000 Hz]
This parameter cannot be adjusted
while the motor is running.
Select the maximum frequency on terminal
X30/6 referring to the output variable in
parameter E-75 Terminal X30/6 Pulse Output
Variable.
This parameter is active when General
Purpose I/O OPCGPIO is installed in the
frequency converter.
Function:
[1 - 4096] Set the encoder pulses per revolution on the
motor shaft. Read the correct value from the
encoder.
3
3
Function: