Parameter Descriptions
K-32 Max Value of Custom Readout
Range:
100 Custom-
[par. K-31 -
ReadoutUnit
999999.99
*
CustomRea-
doutUnit]
K-37 Display Text 1
Range:
Function:
0
[0 -
Enter a text which can be viewed in the graphical
*
25]
display by selecting [37] Display Text 1 in
Parameter K-20 Display Line 1.1 Small,
Parameter K-21 Display Line 1.2 Small,
Parameter K-22 Display Line 1.3 Small,
Parameter K-23 Display Line 2 Large, or
Parameter K-24 Display Line 3 Large.
K-38 Display Text 2
Range:
Function:
0
[0 -
Enter a text which can be viewed in the graphical
*
25]
display by selecting [38] Display Text 2 in
parameter K-20 Display Line 1.1 Small,
parameter K-21 Display Line 1.2 Small,
parameter K-22 Display Line 1.3 Small,
parameter K-23 Display Line 2 Large, or
parameter K-24 Display Line 3 Large.
K-39 Display Text 3
Range:
Function:
0
[0 -
Enter a text which can be viewed in the graphical
*
25]
display by selecting [39] Display Text 3 in
parameter K-20 Display Line 1.1 Small,
parameter K-21 Display Line 1.2 Small,
parameter K-22 Display Line 1.3 Small,
parameter K-23 Display Line 2 Large, or
parameter K-24 Display Line 3 Large.
3.2.5 K-4# Keypad Buttons
Parameters for configuring the graphical keypad Hand, Off,
Auto, & Reset keys.
K-40 [Hand] Button on Keypad
Option:
Function:
[0]
Disabled
Select to disable the key.
DET-618D
AF-650 GP™ Programming Guide
Function:
This parameter sets the
maximum value to be shown
when the speed of the motor
has reached the set value for
parameter F-17 Motor Speed
High Limit [RPM] or
parameter F-15 Motor Speed
High Limit [Hz] (depends on
setting in parameter K-02 Motor
Speed Unit).
02/2016 All rights reserved.
K-40 [Hand] Button on Keypad
Option:
Function:
[1]
Enabled
[Hand ] key enabled.
*
[2]
Password
Avoid unauthorized start in hand-on mode.
Protection
If parameter K-40 [Hand] Button on Keypad is
included in Quick Start Menu, define the
password in parameter K-65 Quick Menu
Password. Otherwise, define the password in
parameter K-60 Main Menu Password.
K-41 [Off] Button on Keypad
Option:
Function:
[0]
Disabled
Avoids accidental stop of the frequency
converter.
[1]
Enabled
[Off] Key enabled
*
[2]
Password
Avoids unauthorized stop. If
Protection
parameter K-41 [Off] Button on Keypad is
included in the Quick Menu, then define the
password in parameter K-65 Quick Menu
Password.
K-42 [Auto] Button on Keypad
Option:
Function:
[0]
Disabled
Avoids accidental start of the frequency
converter in Auto On mode.
[1]
Enabled
[Auto] Key enabled
*
[2]
Password
Avoids unauthorized start in Auto On mode.
Protection
If parameter K-42 [Auto] Button on Keypad is
included in the Quick Menu, then define the
password in parameter K-65 Quick Menu
Password.
K-43 [Reset] Button on Keypad
Option:
Function:
[0]
Disabled
No effect when [Reset] is pressed. Avoids
accidental alarm reset.
[1]
Enabled
[Reset] Key enabled
*
[2]
Password
Avoids unauthorized resetting. If
Protection
parameter K-43 [Reset] Button on Keypad is
included in the Quick Menu, then define the
password in parameter K-65 Quick Menu
Password.
[7]
Enabled
Resets the frequency converter without
without OFF
setting it in Off mode.
[8]
Password
Resets the frequency converter without
without OFF
setting it in Off mode. A password is
required when pressing [Reset] (see option
[2] Password).
3