Problems With Mains Operation/Display - Kessel Pumpfix F Standard Instructions For Assembly, Operation And Maintenance

Control unit/electric components for kessel backwater pumping station for wastewater containing sewage
Table of Contents

Advertisement

Fehleranzeige
Ursache
Max. number of cycles
Power-LED lit
Alarm LED flashing
for pump exceeded
alternating with
flap-LED
Running time limit for pump
Power-LED lit
exceeded
Alarm LED flashing
at the same time as
flap LED
Level fault:
Power-LED lit
Alarm-LED flashing
- Indicator for possible faulty
installation of the probes
- Excessive water seeping
through drain function
8.2 Problems with mains operation / display
Display
8. Fault detection Komfort control unit
Cause
Battery is missing or
faulty
"Battery fault"
- Initialisation: "Motor"
control cable is not
connected, connected
with inverse polarity or
is broken
- During operation:
"motor" control cable
faulty "Motor fault"
- Initialisation: "Motor
probe" control cable is
not connected, con-
nected with inverse
polarity or is broken
- During operation:
"Motor probe" control
cable faulty "Probe
fault"
- Initialisation: Control
cable "Pump" is not
connected, connected
with inverse polarity or
is broken
- During operation:
"Pump" control cable
faulty
"Pump fault"
Remedy
Replace the pump
Inform the customer
service partner
- Reduce water feed at the side
- Check correct connection of the
probe on the control unit
Remove the mains plug, connect
Remedy
batteries, replace by new batte-
ries if necessary
When the unit is ready to func-
tion, a running light appears on
the display again.
Remove the mains plug, dis-
connect the battery; check the
control cable for correct connec-
tion or passage, replace motor if
necessary.
Remove the mains plug, deac-
tivate the battery; check the con-
trol cable for correct connection
or passage, replace motor probe
if necessary.
Remove the mains plug, dis-
connect the battery; check the
control cable for correct connec-
tion or passage, replace pump if
necessary.
18
Notes
Pump service life reached
Pump starts up too often at short
intervals
- Check that the pump probe is
screwed to the red connection
- Check that the motor probe is
connected at the far right
- Initialisation: The system can be put
Notes
into operation, i.e. it is functional. Alarm
can be acknowledged. - Operation: The
fault message appears after a maxi-
mum of 5 minutes. The system is ready
for operation, manual mode is possible.
Fault detection only takes place during
operation (see chapter 8.2 "Additional
functions").
- Initialisation: Cannot be put into ope-
ration
- During operation: Fault detection du-
ring manual operation test cycle/ back-
water
The probe is scanned every 2 seconds.
Fault detection only takes place during
operation (see chapter 8.2 "Additional
functions").
- Initialisation: Cannot be put into ope-
ration
- During operation: Fault detection du-
ring
manual
operation
cycle/backwater
test