Problems With Battery Operation/Power Failure - Diode Display; Problems With Battery Operation/Power Failure - Display - Kessel Pumpfix F Standard Instructions For Assembly, Operation And Maintenance

Control unit/electric components for kessel backwater pumping station for wastewater containing sewage
Table of Contents

Advertisement

8.3 Problems with battery operation / power failure / diode display
Display
Device is in battery operati-
Alarm LED flashing
on; no mains voltage
quickly
- During operation: control
Power LED flas-
cable or "motor" faulty
hing quickly,
Alarm LED flashing
quickly
Flap-LED flashing
quickly
Acoustic signal
- During operation: control
Power LED flas-
cable or "probe" faulty
hing quickly,
Alarm LED flashing
quickly
Backwater-LED
flashing quickly
Acoustic signal
Flap cannot be closed com-
Flap-LED flashing
pletely, i.e. the flap is blocked
quickly
by an object in the backwater
Alarm LED flashing
flap
quickly
Power LED flas-
Backwater detected.
hing quickly,
The flap cannot be closed
Alarm LED flashing
completely, however, i.e. it is
quickly
blocked by an object
Flap-LED flashing
quickly
Acoustic signal
8.4 Problems with battery operation / power failure / display
The display is deactivated in the event of a power failure – power-saving mode. In this case, the diode display is used for
orientation.
8. Fault detection Komfort control unit
Cause
Remedy
Check mains voltage and set up
again if necessary
Deactivate the battery, check con-
trol cable for correct connection and
check throughput;
replace motor if necessary.
Deactivate the battery, check con-
trol cable for correct connection and
check throughput;
replace probe if necessary.
Remove the mains plug, disconnect
the battery, open the Staufix cover,
eliminate the blockage and return to
operation
Close the emergency valve. After
the end of backwater, remove the
blockage as described
20
Notes
The system is functional for 2 hours.
Then the device switches to sleep
mode (see chapter 6.3 Additional
functions)
Fault detection only takes place du-
ring operation
The probe is scanned every 60 se-
conds.
Caution: Check position of the ope-
rating valve! The control attempts to
close the flap 3 x in the interval and
perhaps eliminate the blocking ob-
ject in the process. If the object can
be removed by the flap movement
during these cycles, the system is
ready to be used again. If this does
not work, the system switches to
fault. Acknowledgement of the sig-
nal is possible. It is also possible to
remove the object by flushing the
line. This can be checked by pres-
sing the test key again. In the event
of a negative result, the fault messa-
ge appears again; the object must
be removed as described under re-
medial measures.