Problems With Mains Operation - Display - Kessel Staufix FKA Standard Installation And Operating Manual

Table of Contents

Advertisement

Available languages

Available languages

8. Problems with mains operation of Comfort control unit
8.2 Problems with mains operation / display
Display
Cause
Remove the mains plug, connect
Battery is missing or
batteries, replace by new batte-
faulty
ries if necessary
"Battery fault"
When the unit is ready to func-
tion, a running light appears on
the display again.
- Initialisation: "Motor"
Remove the mains plug, dis-
control cable is not
connect the battery; check the
connected, connected
control cable for correct connec-
with inverse polarity or
tion or passage, replace motor if
is broken
necessary.
- During operation:
"motor" control cable
faulty
"Motor fault"
- Initialisation: "Probe"
Remove the mains plug, deac-
control cable is not
tivate the battery; check the con-
connected, connected
trol cable for correct connection
with inverse polarity or
or passage, replace probe if ne-
is broken
cessary.
- During operation:
"Probe" control cable
faulty
"Probe faulty"
Flap cannot be closed
completely
during
start-up or by the "test"
key, i.e. the flap is
blocked by an object in
the backwater flap
"Flap fault"
- Wrong lever position
during cover fitting
Backwater
detected.
The flap cannot be clo-
sed completely, howe-
ver, i.e. it is blocked by
an object, "Flap fault
during backwater"
Max. number of cy-
cles for flap exceeded
Motor transmitting fi-
gure exceeded
Remedy
Remove the mains plug, deac-
tivate the battery, open the Stau-
fix cover, eliminate the blockage
and return to operation
Recommendation:
Inform a specialist company
- See installation instructions
010-842 (section 4.2.1)
Close the emergency valve.
After the end of backwater, re-
move the blockage as described
Replace motor
Inform the customer service
partner
46
Notes
- Initialisation: The system can be
put into operation, i.e. it is functional.
Alarm can be acknowledged.
- Operation: The fault message ap-
pears after a maximum of 5 minutes.
The system is ready for operation,
manual mode is possible.
Fault detection only takes place du-
ring operation (see chapter 8.2 "Ad-
ditional functions").
- Initialisation: Cannot be put into
operation
- During operation: Fault detection
during
manual
operation
cycle/backwater
The probe is scanned every 2 se-
conds.
Caution: Check position of the ope-
rating valve! The control attempts to
close the flap 3 x in the interval and
perhaps eliminate the blocking object
in the process. If the object can be re-
moved by the flap movement during
these cycles, the system is ready to
be used again. If this does not work,
the system switches to fault. Ackno-
wledgement of the acoustic signal is
possible. It is also possible to remove
the object by flushing the line. This
can be checked by pressing the test
key again. In the event of a negative
result, the fault message appears
again; the object must be removed as
described under remedial measures.
Motor service life reached
Flap closes too often within a short
time
test