Electrical Connection; Control Unit; Mounting The Control Unit On The Wall; Cable Connection - Kessel Pumpfix F Standard Instructions For Assembly, Operation And Maintenance

Control unit/electric components for kessel backwater pumping station for wastewater containing sewage
Table of Contents

Advertisement

2.1 Mounting the control unit on the
wall
The control unit must be installed dry
and frostproof, preferably in the house,
where any alarms that are given can be
seen or heard. Protect from direct sun-
The control unit does not have to be opened
light!
for mounting. Drill two horizontal holes Ø 6
mm at a distance of 168 mm apart (Stan-
dard) or 254 mm apart (Comfort). Screw the
2 rounded head screws 4.5 x 35 mm (TX20)
in as far as necessary for the control unit to
be mounted flush to the wall. Make sure
there is enough distance from the wall on
the right to allow the cover to be opened.
The screws, plastic dowels and drilling tem-
plate are included in the scope of supply.

2.2 Cable connection

Pull the control cables for probe and pump

2.2.1 Standard

through the cable conduit. If necessary
route the cables for the external signal ge-
nerator and the potential-free contact.
Then insert the pump plug (grey, Fig. 1)
and the sensor plug (white, Fig. 2) in the
control unit according to the markings (en-
larged views) and tighten (3 Nm for pump
connection / 1 Nm for probe connection).
Please note:
Grey plug to black socket (pump)
White plug to white socket (opt. probe)
Fig. 1 (grey)
Fig. 2 (white)

2. Electrical connection

Note on cable protection
Where probes and motor cables are expo-
sed, make sure they are protected from ver-
min bites. A suitable protective sheathing
can be obtained through KESSEL custo-
mer services.

2.2.2 Comfort

Here, a further two connections are requi-
red in addition to those described in 2.2.1:
motor probe (Fig. 3) and motor (Fig. 4)
Fig. 4 (grey)
Fig. 3 (white)
Complete connection diagram
From left to right: Pump, pump probe
(red), motor, motor probe (black)
Fig. 5
Probe:

2.3 Probe/motor installation

The optical probe for the pump (red) is mo-
unted in the cover on the inlet side. For this
purpose, the blind plug (lilac) is removed
and the probe is screwed in place hand-tight
using the enclosed screws (2 M5 x 12 scr-
ews TX25 (see Fig. 6).
The same procedure applies for the optical
probe for the motor (black, Fig. 7). However,
this is mounted in the outlet cover – opposi-
te the motor.
4
Fig. 6
black
Fig. 7
red
Fig. 8
Motor:
The levelled drive shaft of the motor must
be in a vertical position (state on delivery).
Move the locking lever of the operating
valve on the locking cover to the "CLO-
SED" position, insert the drive motor into
the drive groove from above, and screw in
place using the four M5 x 12 screws
(TX25) on the locking cover (Fig. 8).
red

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pumpfix f comfort

Table of Contents