Control Unit; Test Standard; Working Conditions; Function Keys - Kessel Pumpfix F Standard Instructions For Assembly, Operation And Maintenance

Control unit/electric components for kessel backwater pumping station for wastewater containing sewage
Table of Contents

Advertisement

3. Putting the Standard unit into operation

3.1 Control unit

The control unit does not have to be
opened for initial operation.
The batteries included in the scope of sup-
ply are already connected and are activa-
ted the first time the unit is connected to
the 230V mains supply. Connect the
mains cable. The control unit carries out a
basic function test, the so-called initialisa-
tion. This is indicated by a running light ap-
prox. 8 sec. after the battery or the mains
cable has been inserted.
During the initialisation procedure, battery,
mains, probe and pump connections are
checked and the pump starts up briefly.
When the control unit has been connected
up correctly, the power LED (green) lights
up. The automatic backwater valve Pump-
fix® F is now ready for operation.
After the system has been put into opera-
tion, the emergency valve (red lever on
the outlet side) has to be opened by hand.
The functional test in accordance with DIN
EN 13564 and the probe test must be car-
ried out (see instructions for Pumpfix® F).

3.2 Test Standard

1. . Hold the pump probe into the water

4.1 Working conditions

Readiness for operation
Pump discharges
against backwater
Backwater

4.2 Function keys

The alarm can be acknowledged by pres-
Alarm key
sing the alarm key. The alarm-LED flas-
hes and thus indicates to the operator that
the fault is still pending.
a
b
"On" level
Pump starts
4. Operating the Standard control unit
Power-LED
Alarm-LED
Power-LED
Alarm-LED
Backwater-LED orange
Flap-LED
Pump-LED
Acoustic Signal
The pump can be actuated manually e.g.
Test key
for maintenance purposes.
The pump is switched on by pressing the
test key.
When the pump is running, the pump LED
flashes.
d
c
i
j
Level-LED lit
Pump-LED lit
Netzbetrieb
green
lit
red
off
green
lit
roed
off
flashing
orange
flashing
orange
flashing
Intermittent sound
6
a) Control unit housing
b) Screwed sealing plug
c) Mains cable
e
d) Brief operating instructions
f
k
e) Green LED "Power"
g
f) Red LED "Alarm"
h
l
g) Level LED
h) Pump LED
i) Connection pump
j) Connection optical probe
k) Alarm key
l) Test key
Batteriebetrieb
off
flashing (1 sec. cycle)
off
off
flashing
off
off
Intermittent sound

4.3 Putting the unit out of operation

After the mains plug has been disconnec-
Caution:
ted, the
alarm key must be pressed for
at least 5 seconds until the signal is soun-
ded. This is to go easy on the battery.