Kramer AFM-20DSP User Manual page 71

20-port audio matrix
Hide thumbs Also See for AFM-20DSP:
Table of Contents

Advertisement

Function
Description
NAME
Set machine (DNS)
name.
The machine name
is not the same as the
model name. The
machine name is used
to identify a specific
machine or a network
in use (with DNS
feature on).
NAME?
Get machine (DNS)
name.
The machine name
is not the same as the
model name. The
machine name is used
to identify a specific
machine or a network
in use (with DNS
feature on).
NAME-RST
Reset machine (DNS)
name to factory
default.
Factory default of
machine (DNS) name
is "KRAMER_" + 4 last
digits of device serial
number.
NET-CONFIG
Set a network
configuration.
Parameters,[DNS1]
and [DNS2]are
optional.
For Backward
id
compatibility, the
parameter can be
omitted. In this case,
the Network ID, by
default, is 0, which is
the Ethernet control
port.
If the gateway
address is not
compliant to the
subnet mask used for
the host IP, the
command will return
an error. Subnet and
gateway compliancy
specified by RFC950.
NET-CONFIG?
Get a network
configuration.
AFM-20DSP – Protocol 3000
Syntax
COMMAND
#NAMEmachine_name<CR>
FEEDBACK
~nn@NAMEmachine_name<CR><LF>
COMMAND
#NAME?<CR>
FEEDBACK
~nn@NAMEmachine_name<CR><LF>
COMMAND
#NAME-RST<CR>
FEEDBACK
~nn@NAME-RSTOK<CR><LF>
COMMAND
#NET-CONFIGid,ip,net_mask,gateway,[DNS1],[DNS2]<CR>
FEEDBACK
~nn@NET-CONFIGid,ip,net_mask,gateway<CR><LF>
COMMAND
#NET-CONFIG?id<CR>
FEEDBACK
~nn@NET-CONFIGid,ip,net_mask,gateway<CR><LF>
Kramer Electronics Ltd.
Parameters/Attributes Example
– String of up to 15
machine_name
alpha-numeric chars (can include
hyphen, not at the beginning or end)
– String of up to 15
machine_name
alpha-numeric chars (can include
hyphen, not at the beginning or end)
id
– Network ID–the device network
interface (if there are more than one).
Counting is 0 based, meaning the
control port is '0', additional ports are
1,2,3....
– Network IP
ip
– Network mask
net_mask
– Network gateway
gateway
id
– Network ID–the device network
interface (if there are more than one).
Counting is 0 based, meaning the
control port is '0', additional ports are
1,2,3....
– Network IP
ip
– Network mask
net_mask
– Network gateway
gateway
Set the DNS name of the
device to room-442:
#NAMEroom-442<CR>
Get the DNS name of the
device:
#NAME?<CR>
Reset the machine name (S/N
last digits are 0102):
#NAME-
RSTKRAMER_0102<CR>
Set the device network
parameters to IP address
192.168.113.10, net mask
255.255.0.0, and gateway
192.168.0.1:
#NET-CONFIG0,192.168.1
13.10,255.255.0.0,192.1
68.0.1<CR>
Get network configuration:
#NET-CONFIG?id<CR>
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afm-20dsp-le

Table of Contents