Function
Description
LOGIN
Set protocol
permission.
For devices that
support security,
LOGIN allows the user
to run commands with
an End User or
Administrator
permission level.
When the permission
system is enabled,
LOGIN enables
running commands
with the User or
Administrator
permission level
When set, login must
be performed upon
each connection
The permission system
works only if security is
enabled with the
"SECUR" command.
It is not mandatory to
enable the permission
system in order to use
the device
In each device, some
connections allow
logging in to different
levels. Some do not
work with security at
all.
Connection may logout
after timeout.
LOGIN?
Get current protocol
permission level.
For devices that
support security,
LOGIN allows the user
to run commands with
an End User or
Administrator
permission level.
In each device, some
connections allow
logging in to different
levels. Some do not
work with security at
all.
Connection may logout
after timeout.
The permission system
works only if security is
enabled with the
"SECUR" command.
LOGOUT
Cancel current
permission level.
Logs out from End
User or Administrator
permission levels to
Not Secure.
Get the last "n" lines of
LOG-TAIL?
message logs.
Used for advanced
troubleshooting. Helps
find error root causes
and gets details not
displayed in the error
code number.
MODEL?
Get device model.
This command
identifies equipment
connected to
AFM-
20DSP
and notifies of
identity changes to the
connected equipment.
The Matrix saves this
data in memory to
answer REMOTE-
INFO requests.
AFM-20DSP – Protocol 3000
Syntax
COMMAND
#LOGINlogin_level,password<CR>
FEEDBACK
~nn@LOGINlogin_level,passwordOK<CR><LF>
or
~nn@LOGINERR004<CR><LF>
(if bad password entered)
COMMAND
#LOGIN?<CR>
FEEDBACK
~nn@LOGINlogin_level<CR><LF>
COMMAND
#LOGOUT<CR>
FEEDBACK
~nn@LOGOUTOK<CR><LF>
COMMAND
#LOG-TAIL?line_num<CR>
FEEDBACK
Get:
~nn@LOG-TAILnn<CR><LF>
Line content
#1<CR><LF>
Line content
#2<CR><LF>
Etc...
COMMAND
#MODEL?<CR>
FEEDBACK
~nn@MODELmodel_name<CR><LF>
Kramer Electronics Ltd.
Parameters/Attributes Example
– Level of permissions
login_level
required ( User or Admin)
– Predefined password (by
password
PASS command). Default password is
an empty string
– Level of permissions
login_level
required (User or Admin)
– Optional, default line_num
Line_num
is 10
– String of up to 19
model_name
printable ASCII chars
Set the protocol permission
level to Admin (when the
password defined in the PASS
command is 33333):
#LOGINAdmin,33333<CR>
Get current protocol permission
level:
#LOGIN?<CR>
#LOGOUT<CR>
Get the last "2" lines of
message logs:
#LOG-TAIL?2<CR>
Get the device model:
#MODEL?<CR>
68