5 – Preventive maintenance
Replace the hydraulic fluid
Do this every 3,000 hours.
Install a new hydraulic filter and filler-breather cap when replacing the hydraulic fluid.
1
Drain valve
2
1-14629 Filler-breather cap
3
Sight gauge
Parts, tools, and materials
1-17473 Hydraulic fluid service kit
Antiwear (AW) mineral oil or synthetic hydraulic
fluid, ISO viscosity grade (VG) 32 or 46
Clean towels
Isopropyl alcohol
Standard 9/16-inch open-ended wrench
(for the drain valve plug)
Standard 15/16-inch crowfoot wrench or socket
(for the access cover)
Do this task when the pump is not running.
84
Do not put too much hydraulic fluid in the tank.
HyPrecision Predictive waterjet pump Operator Manual 810120
2
3
4
1
4
Access cover
1-16025 Hydraulic filter, not shown
Torque wrench
Strap wrench
Hose or pipe for draining hydraulic fluid
Container for used hydraulic fluid
Recommended materials
Clean funnel
Need help?
Do you have a question about the HyPrecision Predictive P-15 and is the answer not in the manual?