5 – Preventive maintenance
This operator interface shows the start procedure stage that the pump is in, a progress, bar, and the target and
output pressures.
HyPrecision Predictive waterjet pump Operator Manual 810120
Stage 1: Supply water pressure
Touch the symbol on the Start Procedure screen.
The beacon light flashes green at 1-second intervals during the start
procedure.
The primary motor starts.
If the system has a boost pump, it turns on.
The hydraulic pump operates at minimum pressure.
The controller monitors the supply water pressure until the pressure
gets to the water manifold pressure setpoint.
The setpoint is based on the pump model.
Stage 2: Remove air from the system
The intensifier starts stroking.
Pump Starting flashes on the screen at 1-second intervals.
The intensifier pushes water through the system and pushes air out
through the bleed-down valve.
Supply water causes the water pressure in the system to increase.
The Supply Water Start Procedure timer expires.
The bleed-down valve is open.
Stage 3: Charge the system
The bleed-down valve closes.
Countdown Starting flashes on the screen at 1-second intervals.
The intensifier strokes to increase the water pressure in the system.
Stage 4: Pressure Increasing
The target pressure increases to 690 bar (10,000 psi).
Pressure Increasing flashes on the screen at 1-second intervals.
The intensifier strokes to increase the water pressure in the system.
133