Make sure that the heat exchanger fan motor turns in the correct direction

1. Operate the pump until the fan turns on.
2. Make sure that the fan motor turns in the direction shown by the rotation arrow.
If the fan motor turns in the wrong direction:
a. Disconnect the electrical power to the pump.
b. In the electrical enclosure, interchange 2 wires on the bottom of the motor starter.
c. Make sure that the fan motor turns in the direction shown by the rotation arrow.