8 – Pump specifications
HyPrecision P-50
Dimensions and weights
Length
Width
Height
The shipping weight is for the pump, the pallet, and the packaging. Exact weights are measured at shipment.
Operating weight is for an unpackaged pump with hydraulic fluid.
Electrical
37 kW, 50 hp
Voltage
Full-load current
Primary circuit breaker rating
The pump uses 3-phase alternating current (AC) electricity. Some parts, such as valve solenoids and sensors,
use 24-volt direct current (VDC) electricity from a power supply in the electrical enclosure.
Water
C
UTTING WATER IN
Flow
Pressure
C
UTTING WATER OUT
Flow
Pressure
Cut pressure factory setpoint
Pierce pressure factory
setpoint
C
and C
OOLING IN
Flow
Pressure
182
178 cm (70 in.)
86 cm (34 in.)
140 cm (55 in.)
73.8 A
80.0 A
(34,500 kPa / 5,000 psi)
(138,000 kPa / 20,000 psi)
OOLING OUT
HyPrecision Predictive waterjet pump Operator Manual 810120
Shipping weight
Operating weight
50 Hz
400 V
208 V to 230 V
138.2 A to 125.8 A
150.0 A
Minimum
7.6 L/minute
(2 gallons/minute)
2.8 bar
(280 kPa / 40 psi)
—
345 bar
—
1,380 bar
11.4 L/minute
(3 gallons/minute)
2.8 bar
(280 kPa / 40 psi)
1,250 kg (2,800 lb)
1,200 kg (2,600 lb)
60 Hz
460 V
62.9 A
80.0 A
Maximum
—
7.6 bar
(760 kPa / 110 psi)
3.8 L/minute
(1 gallon/minute)
4,140 bar
(414,000 kPa / 60,000 psi)
4,140 bar
(414,000 kPa / 60,000 psi)
—
—
7.6 bar
(760 kPa / 110 psi)
Need help?
Do you have a question about the HyPrecision Predictive P-15 and is the answer not in the manual?