Hyprecision P-50S - Hypertherm HyPrecision Predictive P-15 Operator's Manual

Waterjet pumps
Table of Contents

Advertisement

8 – Pump specifications

HyPrecision P-50S

Dimensions and weights
Length
Width
Height
The shipping weight is for the pump, the pallet, and the packaging. Exact weights are measured at shipment.
Operating weight is for an unpackaged pump with hydraulic fluid.
Electrical
37 kW, 50 hp
Voltage
Full-load current
Primary circuit breaker rating
The pump uses 3-phase alternating current (AC) electricity. Some parts, such as valve solenoids and sensors,
use 24-volt direct current (VDC) electricity from a power supply in the electrical enclosure.
Water
C
UTTING WATER IN
Flow
Pressure
C
UTTING WATER OUT
Flow
Pressure
Cut pressure factory setpoint
Pierce pressure factory
setpoint
C
and C
OOLING IN
OOLING OUT
Flow
Pressure
HyPrecision Predictive waterjet pump Operator Manual 810120
196 cm (77 in.)
Shipping weight
97 cm (38 in.)
Operating weight
155 cm (61 in.)
50 Hz
400 V
73.8 A
80.0 A
Minimum
7.6 L/minute
(2 gallons/minute)
2.8 bar
(280 kPa / 40 psi)
345 bar
(34,500 kPa / 5,000 psi)
1,380 bar
(138,000 kPa / 20,000 psi)
11.4 L/minute
(3 gallons/minute)
2.8 bar
(280 kPa / 40 psi)
1,350 kg (3,000 lb)
1,300 kg (2,800 lb)
60 Hz
208 V to 230 V
138.2 A to 125.8 A
150.0 A
Maximum
7.6 bar
(760 kPa / 110 psi)
3.8 L/minute
(1 gallon/minute)
4,140 bar
(414,000 kPa / 60,000 psi)
4,140 bar
(414,000 kPa / 60,000 psi)
7.6 bar
(760 kPa / 110 psi)
460 V
62.9 A
80.0 A
183

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HyPrecision Predictive P-15 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents