7 – Troubleshooting
Operator interface
Operation screen
When the quantity of fluid leaking from the intensifier is less than a set threshold, the intensifier symbol on the
primary operation screen is in its usual state.
Alarms
SMI-related alarms are described here. All other alarms are described starting on page 152.
The controller monitors the pump while it is operating. When the controller senses a problem that is likely to
cause damage to the equipment, the operator interface shows an Alarms screen and the beacon light flashes.s.
Alarm screen on
the operator
interface
Warning
172
Beacon light
Intensifier
Amber, flashing
Enabled
HyPrecision Predictive waterjet pump Operator Manual 810120
Primary motor
On
Cause
The SMI senses that
the seal life remaining is
between 8 hours and
50 hours.
Need help?
Do you have a question about the HyPrecision Predictive P-15 and is the answer not in the manual?