9 – Installation
Compressed air
Air pressure that is too low can prevent the bleed-down valve from closing and can cause the intensifier to
overstroke.
Air pressure that is too high can cause damage to the needle and the seat in the bleed-down valve. If the available
air pressure is too high, install an air regulator (not included) to reduce the pressure.
Receive and unpack the equipment
Lifting must be done by a trained operator.
Obey all work site safety requirements, the safety instructions for the lifting equipment, and the
safety information in this manual.
WARNING
For easy reference, write your pump information on the
this manual (page 11).
Boxes and parts are frequently packed in the pump, or in crates, boxes, and packaging. Look for
accessories and spare parts before discarding the packaging.
1. Examine containers, crates, and pallets for damage.
2. Remove the equipment from the shipping crates and pallets.
3. Examine the equipment to make sure that it was not damaged during shipping. If the equipment is damaged,
a claim must be filed with the carrier.
4. Make sure that the delivery and shipping documents match the equipment that was ordered and what was
received. Report shortages or damages to the OEM or to Hypertherm Waterjet within 10 days of receipt of
the equipment.
5. Make sure that these items are included with the pump.
Dirty water container
Tool kit (optional), refer to page 138
Spare parts kit (optional), refer to page 139
Cord grip connector, two -16 JIC female connectors, and 2 hydraulic hoses for the external heat
exchanger (optional)
The hoses are approximately 9 m (30 feet) long.
The water hose and a cord grip connector for the external boost pump (optional)
These items are usually found in the electrical enclosure:
Key for the L
OCAL
Key for the electrical interlock (optional)
MicroSD card adapter
System schematic drawing
HyPrecision Predictive waterjet pump Operator Manual 810120
/R
key switch
EMOTE
Pump information
page at the front of
199
Need help?
Do you have a question about the HyPrecision Predictive P-15 and is the answer not in the manual?