8 – Pump specifications
Hydraulic fittings
NPT
Hypertherm recommends thread sealant for all NPT fittings.
Size
(inch)
1/4
3/8
1/2
3/4
1
1-1/4
1-1/2
This table shows maximum values. The torque necessary to make a sufficient seal depends on the condition
of the pipe threads and can be much lower than the maximum.
190
Standard
(75% of standard maximum)
N∙m
lbf ∙ ft
34
25
47
35
61
45
75
55
88
65
108
80
129
95
HyPrecision Predictive waterjet pump Operator Manual 810120
Maximum torque value
with thread sealant
N∙m
lbf ∙ ft
26
19
35
26
46
34
56
41
66
49
81
60
96
71
for a male tapered pipe
thread with a female straight
or parallel pipe thread
(50% of standard maximum)
N∙m
lbf ∙ ft
18
13
24
18
31
23
38
28
45
33
54
40
65
48