Do the first start

Use this procedure at installation, when putting the equipment into operation after storage or shipping, and after
maintenance or repairs are done on the intensifier, the high-pressure water system, or the low-pressure water
system.
A
-
IR
COOLED SYSTEM
If the C
exchanger before starting the motor, the hydraulic hoses can be damaged.
CAUTION
If a water line, a fitting, or a valve could be frozen, do not operate the pump. Thaw the equipment
until water moves easily through the water circuit.
Do not do the first start with a diamond orifice installed. There is a possibility that the procedure
can cause damage to the orifice can during the first start.
Hypertherm recommends using a ruby orifice during the first 40 hours of operation.

Do a preoperation inspection

Look for leaks, deterioration, damage, or other conditions that can interfere with operation.
Look at the sight gauge on the hydraulic fluid tank. Add hydraulic fluid, if necessary.
Close all doors and replace all panels and covers, including access covers.
Make sure that all warning decals are visible and legible.

Turn on the utilities

Identify the source of a leak and correct the problem. Refer to Leaks on page 163.
A leak can cause damage to the water fittings.
1. Turn
the electrical breaker.
ON
2. Turn
the water to the pump.
ON
3. Monitor for leaks.
4. Turn
the compressed air supply.
ON
5. Turn
the electrical main.
ON
6. Turn the primary breaker disconnect lever on the electrical enclosure door to
The operator interface screen is on when the pump is energized.
HyPrecision Predictive waterjet pump Operator Manual 810120
hose and the C
OOLING IN
OOLING OUT
hose are not connected to the external heat
.
ON
209