5 – Preventive maintenance
Hydraulic system
Check the hydraulic filter
Do this every work shift.
Replace the hydraulic filter:
•
Every 1,500 hours
•
When the white indicator bar stays in the red zone while the pump is at operating temperature
Refer to Replace the hydraulic filter on page 83 for instructions.
Parts, tools, and materials
Standard screwdriver
Do this task when the pump is running at operating temperature.
Use a standard screwdriver to remove the pump cover.
Make sure that the white indicator bar is not in the red zone.
HyPrecision Predictive waterjet pump Operator Manual 810120
1
1
White indicator bar
2
Red zone
2
81