If you perform automatic gradation adjustment but cannot adjust gradation, density, or color correctly, or scanned error message appears for the test page, set "In-
itialize When Using Full Adjust" to "On", and then perform "Full Adjust".
2) Press "Initialize When Using Full Adjust" > "On" > "OK".
3) Perform Full Adjust.
1.1.7.1.22 How to set Delivery Tray by functions
0031-5497
[ Manual-related ]
Description
Please explain how to set the Delivery Tray by functions.
Field Remedy
Select Settings/Registration > Function Settings > Common > Paper Output Settings > Output Tray Settings > set the output and priority settings for Tray A/B >
press OK.
Factory default settings for Finisher-AM1/Saddle Finisher-AM2 are as follows.